MODEL IDENTIFICATION
1
Code for direct insertion Jupiter
®
2
00
2
D
M
complete code for JUPITER
®
200: direct insertion model
APPROVALS AND HOUSING
BASIC MODEL NUMBER
2 4 Magnetostrictive transmitter with standard HART
®
electronics for level or interface
2 6 Magnetostrictive transmitter with SIL enhanced HART
®
electronics for level or interface
2 7 Magnetostrictive transmitter with standard HART
®
electronics for level and interface
MATERIALS OF CONSTRUCTION
D 1 Standard temperature 316/316L (1.4401/1.4404) max +95 °C (+200 °F)
D 2 Hastelloy C (2.4819) max +95 °C (+200 °F)
D 3 Monel (2.4360) max +95 °C (+200 °F)
D 5 Electropolished 316/316L (1.4401/1.4404) max +95 °C (+200 °F)
D 7 High temperature 316/316L (1.4401/1.4404) max +260 °C (+500 °F)
MOUNTING CONNECTION - SIZE/TYPE (consult factory for other process connections)
FLOAT (for models with 2 floats, consult factory for the lower float)
PROBE LENGTH (specify in cm increments)
5 3 3" 150 lbs. ANSI RF
5 4 3" 300 lbs. ANSI RF
6 3 4" 150 lbs. ANSI RF
6 4 4" 300 lbs. ANSI RF
ANSI flanges
E A DN 80, PN 16 EN 1092-1 Type A
E B DN 80, PN 25/40 EN 1092-1 Type A
F A DN 100, PN 16 EN 1092-1 Type A
F B DN 100, PN 25/40 EN 1092-1 Type A
EN/DIN flanges
11
3/4" NPT thread
22
1" BSP (G1) thread
Threaded
3/4" NPT M20 x 1,5 Cable entry (2 entries - one plugged)
1 2 G
eneral purpose (& I.S. - XP FM/CSA) Cast aluminium housing
3 4 G
eneral purpose (& I.S. - XP FM/CSA) Stainless steel housing
A B ATEX II 1/2G EEx d IIC T6, explosion proof Cast aluminium housing
C D A
TEX II 1/2G EEx d IIC T6, explosion proof Stainless steel housing
E F ATEX II 1G EEx ia IIC T4, intrinsically safe Cast aluminium housing
G H ATEX II 1G EEx ia IIC T4, intrinsically safe Stainless steel housing
Code
Min
S.G.
Max operating pressure in bar (psig)
float
material
Ø x length
in mm (inches)
40 °C
(100 °F)
95 °C
(200 °F)
175 °C
(350 °F)
260 °C
(500 °F)
For level only
AAM
0,84
22,8 (330) 21,0 (305) 18,6 (270) 16,6 (240) 316/316L 50 x 70 (2 x 2.75)
CAM 18,6 (270) 17,6 (255) 16,2 (235) 14,8 (215) Hastelloy C 47 x 76 (1.85 x 3)
ABM
0,70
22,8 (330) 21,0 (305) 18,6 (270) 16,6 (240) 316/316L 58,5 x 76 (2.30 x 3)
BAM 26,2 (380) 23,8 (345) 16,2 (235) 1
1,4 (165)
T
itanium
50 x 70 (2 x 2.75)
CBM 18,6 (270) 17,6 (255) 16,2 (235) 14,8 (215) Hastelloy C 58,5 x 76 (2.30 x 3)
ACM 0,64 22,8 (330) 21,0 (305) 18,6 (270) 16,6 (240) 316/316L 65 x 76 (2.55 x 3)
BBM 0,52 26,2 (380) 23,8 (345) 16,2 (235) 11,4 (165) Titanium 58,5 x 76 (2.30 x 3)
For interface only
MAM
0,89
/
1,00
22,8 (330) 21,0 (305) 18,6 (270) 16,6 (240) 316/316L consult factory
NAM 26,2 (380) 23,8 (345) 16,2 (235) 1
1,4 (165)
T
itanium
consult factory
PAM 18,6 (270) 17,6 (255) 16,2 (235) 14,8 (215) Hastelloy C consult factory
MBM
1,00
/
1,12
22,8 (330) 21,0 (305) 18,6 (270) 16,6 (240) 316/316L consult factory
NBM 26,2 (380) 23,8 (345) 16,2 (235) 11,4 (165) Titanium consult factory
PBM 18,6 (270) 17,6 (255) 16,2 (235) 14,8 (215) Hastelloy C consult factory
Custom float
00M consult factory
0 1 5 min 15 cm (6")
5
7
0
max
570 cm (224")
Refer to dimensions on the left page for proper probe length specification).
L
evel and interface requires 2 floats, order second float separately (see FLOAT selection below)
Density in which the float sinks / Density in which the float floats.